Altronic cpu 95 unit 24v dc altronic 501 061 blue epoxy individual coil. Advantages include a fullfeatured user display and interface, spark characteristic. Exline is a distributor of altronic ignition systems, and altronic engine controls for gas compression engines and compressors. Australia the connection was denied because this country is blocked in the geolocation settings. Altronic cpu95 ignition system products gas engine controls.
The specifications contained herein are not intended as a substitute for established and accepted engineering practices. The secondary analysis capabilities detect shorted spark plugs and leads, as well as spark plugs that exhibit high voltage demend or are not firing at all. Altronic cpu95 ignition system products gas engine. Us7403850b1 automated fault diagnosis method and system for. A blank cpu 95 eeprom, altronic part number 601668a. Jan 26, 2015 we offer mitsubishi tdm48qrc turbo chargers for guascor sfgld480 1800 rpm and guascor sfgld560 1500 rpm natural gas engines. Read online instruction manual improvisa book pdf free download link book now.
These patented diagnostics offer users a means of continually monitoring spark plug. With the altronic cpu95 terminal program software, the user can obtain the full benefit of the capability designed into the cpu95 sys tem. Cpu95evs enhanced varispark digital ignition system provides assured combustion in lean operating environments. You can order the turbo charger in genuine guascor packaging or we can supply you with oem turbo chargers directly from the manufacturers warehouse from japan. An altronic iicpu back cover assembly 2815001 or 2 and mating harness 2930241. Altronic junction box for cpu95 if using a cpu95 ignition and the 2channel ezrail, a replacement cpu95 junction box must also be included because of changes to the wiring scheme. Midas user configurable graphical touch screen and data hub for compressor panels. Altronic ignition systems for industrial engines catalog. Welcome to the altronic product information center. Incorporates altronic patented varispark spark current control technology to assure combustion in lean operating environments, on engines with poorly mixed airfuel charges, under light load, and on lowbtu fuel. This adjustment can be equated to the manual timing switch of the altronic cpu90 system.
The output is an indication that the flow rate is acceptable. An altronic ii cpu back cover assembly 2815001 or 2 and mating harness 2930241. A blank cpu95 eeprom, altronic part number 601668a. Altronic cpu95 ignition simulation on testbed used for programming and diagnosis of ignition system in gas generators. When this status flag is on, the cd200 will test for a match of the in note. Te integrated telematics system for engine and compression control automation. Dayton 2 hp manual submersible sewage pump, 460 voltage. We offer mitsubishi tdm48qrc turbo chargers for guascor sfgld480 1800 rpm and guascor sfgld560 1500 rpm natural gas engines. The ezrail modular ignition rail system is a factorybuilt, tested, and certified assembly designed to eliminate field wiring and troubleshooting. The instrument can read type j thermocouples between. Dsm43820dus installation instructions altronic inc. The automated fault diagnosis method and system accepts, as an input to this module, flow rate measurement from sensor, scanner or plc. Patented cpu95 diagnostics and prognostics predictive diagnostics.
Full access to all cpu95 operating data and control functionality is available through an advanced, user friendly display module as well as via a pc operating the provided cpu95 terminal program. Stulz c2020 controller operating instructions manual pdf. Note that this email is relayed first through the gateway the client host machine doesnt need network access to the smtp server. A means to elevate the cpu95 ignition module to a controlled temperature of 150ef. Continental aircraft engine engine a65 series maintenance manual 32 pages continental aircraft engine engine. Manual or automatic ignition energy level control 3 levels. The disc test for a coming signal pattern observed by the cd200 to the disc. Here you will always find the most recent versions of altronic literature, including sales brochures, operating manuals installation instructions, and more. Ignition systems for industrial engines exline, inc. Cpu95 service instructions ignition system electrical. What is the possible cause of eeprom checksum error. The display module, typically mounted in the engine control panel, gives the user convenient access to critical operating information such as ignition system mode, engine speed, system diagnostics and setup functions. Control panel the control panel houses the sdm and the de3000.
Advantages include a fullfeatured user display and interface, spark characteristic control, advanced timing adjustment options, serial communications, and stateoftheart diagnostics. The altronic cpu95 is a 24 vdcpowered, microprocessorbased digi. Instruction manual improvisa pdf book manual free download. Stulz c2020 controller operating instructions manual pdf view. Patented cpu95 diagnostics and prognostics predictive diagnostics supervise all ignition system related functions. Crankshaftreferenced digital ignition systems altronic cpu95 for medium stationary engines without the addition of special ignition this secondgeneration digital crankshaftcoils or high voltage probes. All books are in clear copy here, and all files are secure so dont worry about it. Altronic cpu95 application guide altronic cpu95 operating instructions. Altronic v is a selfpowered, low tension, capacitor discharge ignition system for 1 to 6 cylinder, 2 or 4 cycle engines. Altronic cpu95 display module with box and paperwork cpu 95 new. Altronic pn 3930182 output harness for alt iiiiiicpuv ignition magneto, cpu95 evs ignition unit to jbox or dcdc power supply for unshielded applications up to 6 cylinders mil connector, 7 pole, socket, 180 180 in length equivalent to. Any design guidelines to prevent this potential failure. Altronic junction box for cpu95 if using a cpu95 ignition and the 2channel ezrail, a replacement cpu95. Altronic ignition accessories are specifically engineered and constructed for troublefree service on demanding 247 oilfield and power generationbased engines.
The altronic cpu95 is a dcpowered, capacitive discharge digital ignition. The altronic v unit can be furnished with any number of output channels between 1 and 6. Us7403850b1 automated fault diagnosis method and system. The altronic cpu95 is a 24 vdcpowered, microprocessorbased digi tal ignition system. This system is fieldprogrammable and offers a variety of advanced control, emissions. Operating instructions cpu95 digital ignition system with enhanced display form cpu95 oie 210. Special cpu referenced system also integrates the altronic cpu 95 is a dcpowered, 95 models. In addition to incorporating a modbus rtuenabled serial port for communication with a remote monitoring system or local controller, the cpu 95evs display module also supports usb connectivity to a pc and the associated. In addition to incorporating a modbus rtuenabled serial port for communication with a remote monitoring system or local controller, the cpu95evs display module also supports usb connectivity to a pc and the associated. Crankshaftreferenced digital ignition systems altronic cpu 95 for medium stationary engines without the addition of special ignition this secondgeneration digital crankshaftcoils or high voltage probes. Lcd displaysthe channel number and the numeric temperature value in ef or ec.
Run a separate conduit to the left entry for all connections to the user interface terminal strips in the ignition module. This site is like a library, you could find million book here by using search box in the header. Altronic cpu95 ignition system the altronic cpu95 is a dcpowered, capacitive discharge digital ignition system applicable to all mediumsized industrial gas engines to 20 cylinders. Altronic v ignition system for 16 cylinder engines. Ignition control visualization powerview3 hmi module altronic cpu95 display screen diagonal 7 inch 178 mm 2. Connect the wiring harness as shown on the following page. These documents are in pdf format and should open in your browser if the adobe reader plugin is installed. Use 24 awg, ul style 1015 wire or shielded cable for these connections. The gas machinery journal is distributed at no charge to industry professionals and toplevel decision makers with responsibility for gas machinery and compressor station design, installation, operation and maintenance. We offer mitsubishi td0936qrc turbo chargers for guascor sfgld series natural gas engines you can order the turbo charger in genuine guascor packaging or we can supply you with oem turbo chargers directly from the. You can order the turbo charger in genuine guascor packaging or we can supply you with oem turbo chargers directly from the. Send us your list of part numbers and quantities for a prompt quotation.
You can send text messages to cell phones and pagers using email. The altronic cpu95 is a dcpowered, capacitive discharge digital ignition system applicable to all mediumsized industrial gas engines to 20 cylinders. For users integrating their cpu95evs system into an existing or planned supervisory control or remote monitoring system, altronic offers its display module. Module and pickup operation, timing input and primary output functions are also. We feature a broad catalog of products available for sale. Both options display essential engine and ignition data such as rpm, timing angle, spark energy level, and diagnostic messages, along with global. Altronics cd200 installation instructions manual pdf download. We offer mitsubishi td0936qrc turbo chargers for guascor sfgld series natural gas engines you can order the turbo charger in genuine guascor packaging or we can supply you with oem turbo chargers directly from the manufacturers warehouse from japan. Altronic cpu95 unit 24v dc altronic 501 061 blue epoxy individual coil magnetic pickup sensor and trigger wheel and halleffect. Terminal program and the enhanced cpu95 display module, the user has the added flexibility and convenience associated with a. Buying, selling, collecting on ebay has never been more exciting. Page 7 altronic cd200 ignition system test disc flag.
The automated fault diagnosis method and system also measures combustion quality of the engine in the enginecompressor set. The display module, typically mounted in the engine control panel, gives the user convenient access to critical operating information such as ignition system. A front mounted keypadserves as the user interface. As a result of this constant attention to product development and manufacturing excellence, engine manufacturers and end users alike from around the world continue to turn to altronic first for technicallyadvanced, highquality ignition systems and components. Enhanced, userfriendly display module insures a convenient means of adjusting.
Patented cpu 95 diagnostics and prognostics predictive diagnostics supervise all ignition system related functions. In order to function properly, the block, liners and heads need to be restored to factory dimensions. For users integrating their cpu 95evs system into an existing or planned supervisory control or remote monitoring system, altronic offers its display module. The gas machinery journal is published by striker enterprises, lp dba striker communications, an independent, privately owned publishing company based in austin, texas. An rs485 two wire serial communications format is used. View and download altronics cd200 installation instructions manual online. Cpu95 operating instructions, enhanced display altronic, llc. This approach insures a maximum return on investment and optimum performance. The altronic cpu95 is a 24 vdcpowered, microprocessorbased digital ignition system designed for application to mediumrange industrial gas engines. Special cpureferenced system also integrates the altronic cpu95 is a dcpowered, 95 models.
Ignition systems and controls keyword found websites. Altronics cd200 installation instructions manual pdf. Gas machinery journal fourth quarter 20 digital edition. Mar 02, 2005 what is the possible cause of eeprom checksum error. The disc test for a coming signal pattern observed by the cd200 to the disc type.
1249 992 1238 1128 567 1229 1470 1177 133 1432 580 1092 1378 186 888 1365 60 97 1403 900 1164 799 996 378 1449 955 1478 970 952 896 1394 1277 189 1354 1331 810 269 619 172 709 774 1237